7.5 Ton, Self-Contained, Air Conditioning Unit ($895.00)
Click Here to contact us about purchasing

7.5 Ton, Self-Contained, Air Conditioning Unit7.5 Ton, Self-Contained, Air Conditioning Unit7.5 Ton, Self-Contained, Air Conditioning Unit

New in Crate with Manuals
7.5 Ton, Self-Contained, Air Conditioning Unit
Corrosion Resistant
Copper/Nickel Piping

  This unit is designed with corrosion resistance piping. Copper/nickel piping in accordance with Mil-F-16420, alloy 706, Type 1, Class 200, Grade 1 is recommended. A strainer is provided(shipped inside the compressor compartment) for installation in the supply line to the unit.
The inlet connection is a union threadpiece and the oulet is a union tailpiece. The mating unions are provided (threaded loosely to the condenser head inlet and water regulating valve outlet). The connection pipe sizes are, Inlet: 1.25 inch and Outlet:1.25 inch.
This unit is designed to mount on a solid surface with (4) 3/4-inch bolts & nuts, with washers. However, the unit can be mounted on structral rails. The rails must be at least 4-1/2 inches wide and positioned at the front, back and sides of the unit.

Removable Plenum comes attached.
  The thermostat can be adjusted to maintain constant room temperature between 60 and 95F.
  The motor pulley is a variable speed pulley that can be adjusted to maintain the proper constant blower speed.
  Installation, Operating and Maintenance manuals are included.

Model # SCAC-7.5

Physical

- Height
-with plenum: 75
-without plenum: 65
-width (in.): 48
-Depth (in.): 25
-Weight (lbs.) with controller
-Dry: 1100

Minimum Air Flow (CFM): 2250
Capacity (Btu/hr)
-Normal: 90,800
-Overload: 112,500

Waterflow (GPM)
-Normal: 28
-Overload: 35

Blower Speed (RPM)
-Wet: 1125
-with plenum: 900
-without plenum: 1130

Refrigerant Type: R-22
Refrigerant Charge (lbs): 20

Electrical Data 
-Power Supply (3ph-60Hz-440V)
-Current (Amps)
-Normal: 13.3
-Overload: 14.5
-Power Input (Watts)
-Normal: 9060
-Overload: 9762

Normal: Based on 80F dry bulb/ 67F wet bulb entering air temperature, 95F entering water temperature, and 35 psig entering water pressure. Overload: Based on 100F dry bulb/85F wet bulb entering air temperature, 100F entering water temperature, and 35 psig entering water pressure.

Shipping Weight: 1365LBS.